中文
Home >> Product >> UPS
Your location:Home >> Product >> UPS

Product

contact us

Shenzhen Wenrui Power Technology Co., Ltd
contacts:Miss Huang
telephone:+86 15012575668

Factory address:Building 2, 1st Gongyi Road, Loucun Community, Xinhu Street, Guangming District, Shenzhen

D series high-frequency online UPS 6~20kVA

Digital Series (parallel redundancy) UPS D6KS ~ 3 D 20 KS with double conversion pure online architecture, the architecture can block the impact of abnormal power on the load, at the same time also can guarantee the stable and reliable output, let the safety of the load, is the best can effectively solve the problem of all power architecture design, using digital control technology (DSP / MCU chip), can choose the function of parallel expansion and parallel redundancy, provide the user with power planning elasticity and more secure guarantee.



Contact number:+86 15012575668
Basic Features

Smaller design

The application of advanced control technology, greatly improve the power factor, small volume, light weight.


Online maintenance design (optional)

If you select the maintenance switch, you can safely carry out online maintenance under the condition of continuous load power supply as long as you turn the UPS to the maintenance mode; If you plan for N+1 parallel redundancy, even if the mains power is interrupted during maintenance, your valuable equipment can get uninterrupted high-quality power supply.


Comprehensive functional design

DC start function enables you to use UPS without mains power supply. The function of timing on/off and remote monitoring can realize the goal of unmanned. The powerful charging function is convenient for you to extend the standby time. The intelligent charging mode extends the battery life and saves

money. The automatic restart function makes it unnecessary for you to turn on the UPS in person after the standby UPS is turned off. Comprehensive functional design brings more convenience to your work.


Excellent technical indicators

The input power factor close to 1 greatly reduces the pollution to the municipal power grid, improves the utilization of the grid, and is a real green power source. The ultra wide input voltage range provides the most complete protection for your valuable equipment under various harsh power environments.

Nearly 93% full load operation efficiency, effectively saving your electricity bill. Strong anti-interference ability, meeting the requirements of IEC61000-4 for electromagnetic interference, can effectively eliminate noise, high voltage and breakthrough on the power grid, and provide a clean power environment for your

equipment.

1.png


Intelligent power supply monitoring and management software: UPSILON 2000

Support Microsoft Windows95/98/Me/NT/2000/XP/Linux operating system, applicable to TCP/IP LAN, and support TCP/IP network monitoring UPS; Provide hierarchical directory structure management network UPS; Abnormal event notification; Automatically detect UPS model and communication port; Provide password protection; UPS can be switched on/off regularly; Support UPS timing self-test function; Support graphic real-time display of UPS status; Support network shutdown of servers and workstations; Support closing most applications and saving related documents; Support multi language and English platforms; Support online help function. It has the function of data recording (including mains power, UPS, load, battery) and event log, which is convenient for the system administrator to carry out daily UPS maintenance. 


Complete monitoring and communication function 

RS-232, intelligent slot (Intelligent Slot) and other monitoring and communication interfaces are provided. Users can realize centralized monitoring and remote monitoring functions through the SNMP network card.


Technical Specifications

1.jpg

1. Optional rated capacity (output power) PF = 0.8.

2. The model with "S" is a extended time model, and the battery should be configured according to the external battery DC voltage according to the battery life time.

3. Load in high altitude = rated power x reduction coefficient

Altitude (m)

1000

1500

2000

2500

3000

3500

4000

4500

5000

Frequency reduction coefficient

100%

95%

91%

86%

82%

78%

74%

70%

67%

 If the UPS is used above 1000m, the decreasing rated output must be used, as shown in the table above.

* The above parameters may be adjusted and changed, please refer to the physical object.


Basic Features

Smaller design

The application of advanced control technology, greatly improve the power factor, small volume, light weight.


Online maintenance design (optional)

If you select the maintenance switch, you can safely carry out online maintenance under the condition of continuous load power supply as long as you turn the UPS to the maintenance mode; If you plan for N+1 parallel redundancy, even if the mains power is interrupted during maintenance, your valuable equipment can get uninterrupted high-quality power supply.


Comprehensive functional design

DC start function enables you to use UPS without mains power supply. The function of timing on/off and remote monitoring can realize the goal of unmanned. The powerful charging function is convenient for you to extend the standby time. The intelligent charging mode extends the battery life and saves

money. The automatic restart function makes it unnecessary for you to turn on the UPS in person after the standby UPS is turned off. Comprehensive functional design brings more convenience to your work.


Excellent technical indicators

The input power factor close to 1 greatly reduces the pollution to the municipal power grid, improves the utilization of the grid, and is a real green power source. The ultra wide input voltage range provides the most complete protection for your valuable equipment under various harsh power environments.

Nearly 93% full load operation efficiency, effectively saving your electricity bill. Strong anti-interference ability, meeting the requirements of IEC61000-4 for electromagnetic interference, can effectively eliminate noise, high voltage and breakthrough on the power grid, and provide a clean power environment for your

equipment.

1.png


Intelligent power supply monitoring and management software: UPSILON 2000

Support Microsoft Windows95/98/Me/NT/2000/XP/Linux operating system, applicable to TCP/IP LAN, and support TCP/IP network monitoring UPS; Provide hierarchical directory structure management network UPS; Abnormal event notification; Automatically detect UPS model and communication port; Provide password protection; UPS can be switched on/off regularly; Support UPS timing self-test function; Support graphic real-time display of UPS status; Support network shutdown of servers and workstations; Support closing most applications and saving related documents; Support multi language and English platforms; Support online help function. It has the function of data recording (including mains power, UPS, load, battery) and event log, which is convenient for the system administrator to carry out daily UPS maintenance. 


Complete monitoring and communication function 

RS-232, intelligent slot (Intelligent Slot) and other monitoring and communication interfaces are provided. Users can realize centralized monitoring and remote monitoring functions through the SNMP network card.


Technical Specifications

1.jpg

1. Optional rated capacity (output power) PF = 0.8.

2. The model with "S" is a extended time model, and the battery should be configured according to the external battery DC voltage according to the battery life time.

3. Load in high altitude = rated power x reduction coefficient

Altitude (m)

1000

1500

2000

2500

3000

3500

4000

4500

5000

Frequency reduction coefficient

100%

95%

91%

86%

82%

78%

74%

70%

67%

 If the UPS is used above 1000m, the decreasing rated output must be used, as shown in the table above.

* The above parameters may be adjusted and changed, please refer to the physical object.


Basic Features

Smaller design

The application of advanced control technology, greatly improve the power factor, small volume, light weight.


Online maintenance design (optional)

If you select the maintenance switch, you can safely carry out online maintenance under the condition of continuous load power supply as long as you turn the UPS to the maintenance mode; If you plan for N+1 parallel redundancy, even if the mains power is interrupted during maintenance, your valuable equipment can get uninterrupted high-quality power supply.


Comprehensive functional design

DC start function enables you to use UPS without mains power supply. The function of timing on/off and remote monitoring can realize the goal of unmanned. The powerful charging function is convenient for you to extend the standby time. The intelligent charging mode extends the battery life and saves

money. The automatic restart function makes it unnecessary for you to turn on the UPS in person after the standby UPS is turned off. Comprehensive functional design brings more convenience to your work.


Excellent technical indicators

The input power factor close to 1 greatly reduces the pollution to the municipal power grid, improves the utilization of the grid, and is a real green power source. The ultra wide input voltage range provides the most complete protection for your valuable equipment under various harsh power environments.

Nearly 93% full load operation efficiency, effectively saving your electricity bill. Strong anti-interference ability, meeting the requirements of IEC61000-4 for electromagnetic interference, can effectively eliminate noise, high voltage and breakthrough on the power grid, and provide a clean power environment for your

equipment.

1.png


Intelligent power supply monitoring and management software: UPSILON 2000

Support Microsoft Windows95/98/Me/NT/2000/XP/Linux operating system, applicable to TCP/IP LAN, and support TCP/IP network monitoring UPS; Provide hierarchical directory structure management network UPS; Abnormal event notification; Automatically detect UPS model and communication port; Provide password protection; UPS can be switched on/off regularly; Support UPS timing self-test function; Support graphic real-time display of UPS status; Support network shutdown of servers and workstations; Support closing most applications and saving related documents; Support multi language and English platforms; Support online help function. It has the function of data recording (including mains power, UPS, load, battery) and event log, which is convenient for the system administrator to carry out daily UPS maintenance. 


Complete monitoring and communication function 

RS-232, intelligent slot (Intelligent Slot) and other monitoring and communication interfaces are provided. Users can realize centralized monitoring and remote monitoring functions through the SNMP network card.


Technical Specifications

1.jpg

1. Optional rated capacity (output power) PF = 0.8.

2. The model with "S" is a extended time model, and the battery should be configured according to the external battery DC voltage according to the battery life time.

3. Load in high altitude = rated power x reduction coefficient

Altitude (m)

1000

1500

2000

2500

3000

3500

4000

4500

5000

Frequency reduction coefficient

100%

95%

91%

86%

82%

78%

74%

70%

67%

 If the UPS is used above 1000m, the decreasing rated output must be used, as shown in the table above.

* The above parameters may be adjusted and changed, please refer to the physical object.


Basic Features

Smaller design

The application of advanced control technology, greatly improve the power factor, small volume, light weight.


Online maintenance design (optional)

If you select the maintenance switch, you can safely carry out online maintenance under the condition of continuous load power supply as long as you turn the UPS to the maintenance mode; If you plan for N+1 parallel redundancy, even if the mains power is interrupted during maintenance, your valuable equipment can get uninterrupted high-quality power supply.


Comprehensive functional design

DC start function enables you to use UPS without mains power supply. The function of timing on/off and remote monitoring can realize the goal of unmanned. The powerful charging function is convenient for you to extend the standby time. The intelligent charging mode extends the battery life and saves

money. The automatic restart function makes it unnecessary for you to turn on the UPS in person after the standby UPS is turned off. Comprehensive functional design brings more convenience to your work.


Excellent technical indicators

The input power factor close to 1 greatly reduces the pollution to the municipal power grid, improves the utilization of the grid, and is a real green power source. The ultra wide input voltage range provides the most complete protection for your valuable equipment under various harsh power environments.

Nearly 93% full load operation efficiency, effectively saving your electricity bill. Strong anti-interference ability, meeting the requirements of IEC61000-4 for electromagnetic interference, can effectively eliminate noise, high voltage and breakthrough on the power grid, and provide a clean power environment for your

equipment.

1.png


Intelligent power supply monitoring and management software: UPSILON 2000

Support Microsoft Windows95/98/Me/NT/2000/XP/Linux operating system, applicable to TCP/IP LAN, and support TCP/IP network monitoring UPS; Provide hierarchical directory structure management network UPS; Abnormal event notification; Automatically detect UPS model and communication port; Provide password protection; UPS can be switched on/off regularly; Support UPS timing self-test function; Support graphic real-time display of UPS status; Support network shutdown of servers and workstations; Support closing most applications and saving related documents; Support multi language and English platforms; Support online help function. It has the function of data recording (including mains power, UPS, load, battery) and event log, which is convenient for the system administrator to carry out daily UPS maintenance. 


Complete monitoring and communication function 

RS-232, intelligent slot (Intelligent Slot) and other monitoring and communication interfaces are provided. Users can realize centralized monitoring and remote monitoring functions through the SNMP network card.


Technical Specifications

1.jpg

1. Optional rated capacity (output power) PF = 0.8.

2. The model with "S" is a extended time model, and the battery should be configured according to the external battery DC voltage according to the battery life time.

3. Load in high altitude = rated power x reduction coefficient

Altitude (m)

1000

1500

2000

2500

3000

3500

4000

4500

5000

Frequency reduction coefficient

100%

95%

91%

86%

82%

78%

74%

70%

67%

 If the UPS is used above 1000m, the decreasing rated output must be used, as shown in the table above.

* The above parameters may be adjusted and changed, please refer to the physical object.


Basic Features

Smaller design

The application of advanced control technology, greatly improve the power factor, small volume, light weight.


Online maintenance design (optional)

If you select the maintenance switch, you can safely carry out online maintenance under the condition of continuous load power supply as long as you turn the UPS to the maintenance mode; If you plan for N+1 parallel redundancy, even if the mains power is interrupted during maintenance, your valuable equipment can get uninterrupted high-quality power supply.


Comprehensive functional design

DC start function enables you to use UPS without mains power supply. The function of timing on/off and remote monitoring can realize the goal of unmanned. The powerful charging function is convenient for you to extend the standby time. The intelligent charging mode extends the battery life and saves

money. The automatic restart function makes it unnecessary for you to turn on the UPS in person after the standby UPS is turned off. Comprehensive functional design brings more convenience to your work.


Excellent technical indicators

The input power factor close to 1 greatly reduces the pollution to the municipal power grid, improves the utilization of the grid, and is a real green power source. The ultra wide input voltage range provides the most complete protection for your valuable equipment under various harsh power environments.

Nearly 93% full load operation efficiency, effectively saving your electricity bill. Strong anti-interference ability, meeting the requirements of IEC61000-4 for electromagnetic interference, can effectively eliminate noise, high voltage and breakthrough on the power grid, and provide a clean power environment for your

equipment.

1.png


Intelligent power supply monitoring and management software: UPSILON 2000

Support Microsoft Windows95/98/Me/NT/2000/XP/Linux operating system, applicable to TCP/IP LAN, and support TCP/IP network monitoring UPS; Provide hierarchical directory structure management network UPS; Abnormal event notification; Automatically detect UPS model and communication port; Provide password protection; UPS can be switched on/off regularly; Support UPS timing self-test function; Support graphic real-time display of UPS status; Support network shutdown of servers and workstations; Support closing most applications and saving related documents; Support multi language and English platforms; Support online help function. It has the function of data recording (including mains power, UPS, load, battery) and event log, which is convenient for the system administrator to carry out daily UPS maintenance. 


Complete monitoring and communication function 

RS-232, intelligent slot (Intelligent Slot) and other monitoring and communication interfaces are provided. Users can realize centralized monitoring and remote monitoring functions through the SNMP network card.


Technical Specifications

1.jpg

1. Optional rated capacity (output power) PF = 0.8.

2. The model with "S" is a extended time model, and the battery should be configured according to the external battery DC voltage according to the battery life time.

3. Load in high altitude = rated power x reduction coefficient

Altitude (m)

1000

1500

2000

2500

3000

3500

4000

4500

5000

Frequency reduction coefficient

100%

95%

91%

86%

82%

78%

74%

70%

67%

 If the UPS is used above 1000m, the decreasing rated output must be used, as shown in the table above.

* The above parameters may be adjusted and changed, please refer to the physical object.


Copyright © 2018-2020 ShenZhen Wenrui Power Technology Co., Ltd
Company address:Building 2, 1st Gongyi Road, Loucun Community, Xinhu Street, Guangming District, Shenzhen
home
Telephone consultation
WeChat consultation
Online Message